4000A 11kv Indoor Three Phases Isolation Switch with Motor Operating Mechanism

Lugar de origen Wenzhou
Nombre de la marca QIUPU
Certificación IEC
Número de modelo GN22-12/4000A
Cantidad de orden mínima 10 por ciento
Detalles de empaquetado WOODENS
Tiempo de entrega 7 días
Condiciones de pago T/t, unión occidental
Capacidad de la fuente 50000 PC/mes

Éntreme en contacto con gratis las muestras y los vales.

whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

Si usted tiene alguna preocupación, proporcionamos ayuda en línea de 24 horas.

x
Datos del producto
Voltaje de velocidad 11 kV Calificar la corriente Cuadrados de las unidades
Corriente estable caliente 12.5kA/4S Corriente de Satble del movimiento 31.5kA/4S
Ancho 480 mm Corriente corta 40ka
Deja un mensaje
Descripción de producto

4000A 11kv Indoor Three Phases Isolation Switch with Motor Operating Mechanism

 

 

        1. We are specialty on epoxy resin medium voltage and high voltage components, such as 10KV, 24 KV and 40.5KV Circuit Breaker , Load breaker switch , Disconnecting Switch , Epoxy resin switchgear bushing , contactor box , insulators and transformer . 630A, 1250 A ,2500A , 3150A and 4000A contact box , club contact , fix contact, arm contact and jaw contact . 630A and 1250A VS1 circuit breaker . 630A and 1250A ZN85-40.5 circuit breaker . 12KV and 24KV earth switch. KYN28A-12 and KYN61 high voltage switchgear components!

 

        2. The Indoor high voltage isolation switch GN22-12(C) is use for three phase alternating current 50Hz , rate voltage is 12kV .

        3. Altitude is less than 1000 M .

 

        4. It is mainly used for "isolation power supply, turndown operation, for connecting and cutting off small current circuit", without arc extinguishing function.
The isolation switch, usually referred to as the high voltage isolation switch, is rated voltage above 1kV isolation switch, is the most used high voltage switch electrical appliances, working principle and structure is relatively simple, but because of the high usage, high reliability requirements, the design, construction and safe operation of power substation, power plant has a great impact.

 

 

Item Technical data
Rated voltage (KV)     12    
Rated frequency(Hz) 50
Insulator(capacity) insulating Frequency withstand voltage 5 min (KV)     42    
Frequency withstand voltage 1 min (V) 2000
Lighting impulse withstand voltage (KV)     75    
humitity 90%
light frequency voltage 85kV
   

 